Plug In Zirconia Portable Trace Oxygen Analyzer Quick Response

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | ZN3001 Plug In Trace Oxygen Analyzer | Measuring Range | 0.01×10-6~25.0% O2 Full Scale |
---|---|---|---|
Response Time | T90< 5 Sec | Resolution | 0.1×10-6 |
Size | 270mmx132mmx320mm | Weight | 6kg |
Highlight | Atex Portable Trace Oxygen Analyzer,Quick Response Portable Trace Oxygen Analyzer,Zirconia Oxygen Analyzer |
Zetron ZN3001 Plug-in Trace Oxygen Analyzer
ZN3001 Zirconia Oxygen Analyzer is composed of an intelligent signal converter with microprocessor as its core and an imported zirconia detector and used for online detection of oxygen content in the gas detected.
- Zirconia detector adopted, featuring long service life, stable performance, and quick response;
- Wide measurement range, available for analysis from trace oxygen to macro oxygen;
- 128×64 lattice LCD, able to simultaneously display parameters like oxygen content, date, and time;
- Timed automatic storing function, and stored data available for viewing at any time;
- Automatic range shifting; alarm point can be set at will within the whole range;
- Standard RS232 or RS485 communication interface available for two-way communication with computer;
- Alarm for out-of-control temperature;
- Display switchable between oxygen content, potential value, and operating furnace temperature;
- Built-in air extracting pump and external filter can be added upon selection.
Measurement range |
0.01×10-6~25.0% O2 full scale; |
Accuracy |
≤±5% F.S (0.0~10×10-6); ≤±2% F.S (10~100×10-6); |
Resolution |
≤ ±1.5% |
Stability |
Zero drift ≤ ±2% FS/7d; Span drift ≤ ±2% FS/7d |
Response time |
90 ≤ 15 sec |
Sample gas flow |
400±10 ml/min |
Sample gas pressure |
0.05 MPa ≤ Inlet Pressure ≤ 0.25 MPa; |
Output signal |
4~20 mA |
Operating environment |
Temperature: -5℃~+45℃; |
Operating power supply |
1. 220 VAC±10%, 50 Hz±5%; 2. Rechargeable lithium-ion battery built in the instrument; |
Overall dimensions |
270 mm (W) × 132 mm (H) × 450 mm (D) |
Weight |
6kg |
Operatiing Temperature | 750℃ |
Automatic analysis on oxygen content in nitrogen or argon in electric power, metallurgy, and air separation industries.