-
Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
Gas Detector Sensor
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
TH-1000 GPRS Cems Continuous Emission Monitoring System On Line Monitoring And Pretreatment

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Emission Monitoring System | Model Number | TH1000 |
---|---|---|---|
Gas Unit | PPM, Mg/m3, Vol%, LEL%, PPHM, Ppb, Mg/l. | Detecting Gas | Toxic Gases, Oxygen, Carbon Dioxide, Flammable And Explosive Gases, TVOC, Etc. |
Warranty | 12 Months | Color | Black |
Customized Support | OEM, ODM, OBM | Weight | 1.8Kg(Probes) |
Size | 400×180×600mm(L×H×W) | ||
Highlight | th 1000 cems continuous emission monitoring system,gprs continuous emission monitoring system,cems continuous emission monitoring system |
TH-1000 Continuous Emission Monitoring System
The online monitoring and pretreatment system is applied to 24-hour continuous online monitoring of on-site gas concentration. It is equipped with a 7-inch high-definition color screen to display on-site concentration, over standard on-site audible and visual alarm (optional), remote signal GPRS, DTU, Lora, and another transmission. The gas sensor of an internationally famous brand is adopted. The main detection principles include gas sensors based on the principles of electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photo ion, etc.
- Optional 1-6 kinds of compound gas detectors
- The concentration display unit can be switched freely
- A variety of communication methods are available
- Real-time monitoring via wired or wireless remote transmission, network transmission; 3-wire 4-20mA standard signal and standard bus RS485 (Modbus-RTU) output at the same time; optional frequency output 200-1000Hz, Hart protocol signal, 1-5V output, 2-wire 4-20mA, SMS alarm, wireless transmission (2-5km or unlimited distance); compatible with secondary instruments, data acquisition modules, PLC, DCS system, can drive related equipment.
- Infrared remote control
- Standard infrared remote control, through the infrared remote control function keys, can be a one-touch operation, can realize on dangerous occasions without opening the cover operation, such as: modifying the alarm point, concentration calibration, zero calibration, silence, restore factory, and other functions.
- Rich human-machine interface
- 1.7" HD color screen, display real-time concentration, alarm status.
- High-temperature gas detection (optional)
- Optional high temperature and high humidity pre-treatment systems can detect high-temperature flue gas.
- Data recovery function, you can select partial or full recovery in case of misoperation
- The maximum value and minimum value can be set to be displayed or not
- Multiple alarm modes, a multi-directional indication of alarm status during alarm
- Include 2 groups of relay switch output, sound and light alarm (optional), display visual alarm.
- Alarm types include concentration alarm, fault alarm.
- Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm
- Misoperation identification function: concentration calibration misoperation is automatically identified and prevented to avoid bad human factors
- Zero-point automatic tracking, long-term use is not affected by zero-point drift
- Multi-stage calibration of target point to ensure linearity and accuracy of measurement
- Chinese or English interface can be selected
- Wide working temperature: -40~+70℃, support temperature compensation
- Logging
- Record calibration log, maintenance log, fault record, troubleshooting countermeasures, sensor life expiration reminder, next concentration calibration time reminder function.
- Intrinsically safe circuit design, explosion-proof, with secondary lightning protection and anti-static capability. Meet national standards and resist high-intensity pulse surge current impact. With anti-reverse connection function. Meets EMI, EMC standards.
All the cases require the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Q: When do you reply to messages?
A: We will reply you for your inquiry in 24 hours.
Q: When do you send the products? And how do you send it ?
A: For the small order, we will send out the goods with 5 days,If have stock ,we will send immediately.
We send them by ups, fedex, tnt or dhl. For big order, normal is 20 days will finish.
Q:Do you accept OEM or revised logo, color, model,size?
A:Yes, we accept OEM for the qualify buyer. We can make the products according to customer personal requirement.
Q: How about the quality of the managements ?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before ,
shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.
Q: How about your after-sale service?
A: After sending, we will track the products for you , until you get the products.
When you got the goods, test them, and give me a feedback.
If you have any questions about the problem, contact with us, we will offer the solve way for you.