• Beijing Zetron Technology Co., Ltd
    Dora
    Hello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
  • Beijing Zetron Technology Co., Ltd
    Sylvia
    Good gas leak detection instrument !!! High accurate test values :D
Contact Person : Lisa Niu
Phone Number : +86 15699785629
Whatsapp : +8615699785629

Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light

Place of Origin China
Brand Name Zetron
Certification CE, ISO13485, ISO9001
Model Number UVOZ-3300C
Minimum Order Quantity 1
Packaging Details paper carton
Delivery Time 3-7 days
Payment Terms T/T, L/C, Western Union, MoneyGram
Supply Ability 10000 set/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Model UVOZ-3300C Measuring Range 0-300g/Nm3
Gas Flow 0.5L ± 0.2L/min Ambient Temperature -20 To 50°C
Dimensions 230mm (H) X 330mm (W) X 150mm (D) Warranty 1 Year
Highlight

wall mounted o3 detector

,

uv light o3 detector

,

wall mounted portable ozone detector

Leave a Message
Product Description

UVOZ-3300C Ozone Gas Analyser

OVERVIEW

 

The UVOZ-3300C ozone gas analyser calculates the current ozone concentration by measuring the change in light signal intensity before and after ozone absorption of UV light. The equipment uses an advanced dual-light UV light source system with an intelligent lamp management system, which enables the UV lamp to reach the measurement state quickly after switching on. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, vessels and other environments. It is widely used in pharmaceutical, chemical, municipal and wastewater treatment industries for the measurement of ozone generator outlet concentration and ozone generator output.
The ozone analyser has a touch screen operator interface with real time display of ozone gas concentration, with pressure and temperature compensation and display, and can be set for automatic zero time and manual zeroing mode. High concentration (g/Nm3) range with flow input and real time display of ozone generator output. Two sets of relay signal outputs are available, allowing the user to choose between high and low alarm point signal output connections. The core component adopts UV long life light source system with high transmittance quartz sheet to ensure the stability of the zero point and prevent the zero point drift from affecting the accuracy of the detection concentration. According to the foreign light cell technology design of pressure-resistant, impact-resistant independent light cell structure, zero calibration operation gas flow, pressure, flow rate remains unchanged, to prevent the impact of airflow on the zero calibration, without closing the ozone inlet can complete the zero calibration operation, to ensure that the equipment can be 24 hours a day continuous operation.

 
FEATURES

 

Measurement features: patented process with automatic zero correction, dual-optical UV absorption method principle, foreign long-life UV LED light source, continuous operation, ensuring the stability of the detection concentration.
Test method: Dual-optical UV absorption method, long-life light source system, high measurement accuracy
Measurement principle: accurate measurement by photometric absorption principle according to Lambert-Beer's law.
Light source system: foreign long-life UV light source system (UV LED light source (with lens)), free 2-year guarantee.
Usage: Indoor installation with power and signal terminals.
Light cell system: Separate light cell technology, no leakage, high pressure resistance, high flow sampling gas impact resistance.
Intelligent compensation: built-in temperature and pressure compensation and display, with automatic compensation of the light source.
Operation mode: User can choose between manual zero calibration and automatic zero calibration according to the operating status, and can set the automatic zero calibration time.
Display units: g/Nm3, mg/NL optional.
Data display: HD colour touch screen, high concentration range setting for incoming gas mass flow, real time display of yield (optional).
Output functions: 4-20mA, RS485 communication, two sets of alarm point output, electronic flowmeter input, etc.
Standard equipment: anti-corrosion flow meter, ozone tail gas destroyer, inlet gas filter.

 

PARAMETER

 

Model UVOZ-3300C
Measuring range 0-300g/Nm3
Optional ranges 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm
Light source life approx. 30,000 - 50,000 hours
Sampling method positive pressure sampling, negative pressure sampling (optional)
Display interface 4.3" touch screen operator interface
Content interface ozone concentration, temperature, pressure
Auxiliary functions Temperature compensation, pressure compensation
Display units g/Nm3, mg/NL, %WT optional
Display resolution 0.01g/Nm3
Gas flow 0.5L ± 0.2L/min
Input pressure <0.1 MPa
Concentration error 0.5% FS max
Linearity error 0.5% FS max
Zero point drift <±0.3%.FS
Response time 0.03 s for signal, 0.3 s for display
Ambient temperature -20 to 50°C
Piping connection Quick screw (stainless steel)
Tandem sample aperture Φ8 (8mm*6mm) (optional)
Bypass sampling aperture Φ6 (6mm*4mm)
Communication method RS-485
Output mode 4-20mA (active)
Relay signal relay signal for high alarm point, relay signal for low alarm point
Power supply AC 110-220V
Dimensions 230mm (H) x 330mm (W) x 150mm (D)
Note 1mg/L = 1g/m3 = 467PPM.
Free warranty 24 months (mainframe sensor)
 

Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light 0

 

Wall Mounted O3 Detector Ozone Gas Concentration Analyser Absorption Of Uv Light 1

TAG

Ozone gas analyser,Ozone detector,Gas concentration analyzer,Ozone monitor,Ozone concentration detector, OEM/ODM service.