MIC500S Pipe Mounted Gas Concentration Detector with Relay

Place of Origin China
Brand Name Zetron
Certification CE
Model Number MIC500
Minimum Order Quantity 1 set
Price USD 890/set - 7298/set
Packaging Details 230x210x120 mm
Delivery Time 1-10 work days
Payment Terms T/T, Western Union, MoneyGram, D/P, D/A, L/C
Supply Ability 1000 SET / week

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name MIC500S Pipe Mounted Gas Concentration Detector With Relay Type Fixed Type
Function Measure Gas Purity Sensor Type Imported Electrochemical Sensor
Detecting Gas Combustible Gas/H2S/CO/O2/H2S/H2 Connection 4-20mA, RS485, Hart, Relay
Customized Support OEM, ODM, OBM Weight 2.5kg
Highlight

MIC500S Gas Concentration Detector

,

Pipe Mounted Gas Concentration Detector

,

Relay Gas Concentration Detector

Leave a Message
Product Description

MIC500S Pipe Mounted Gas Concentration Detector with Relay 

OVERVIEW

 

1. Petrochemical Industry ‌
In refineries, natural gas processing plants, chemical plants and other scenarios, H₂S often accompanies oil and gas leaks and escapes during the reaction process. Detectors installed in pipelines, storage tanks, and production workshops can monitor gas concentrations in real time, link ventilation systems, and avoid the risk of poisoning and explosion.

‌2. Sewage Treatment and Municipal Engineering ‌
H₂S is easily accumulated in confined spaces such as sewers, sewage pools, and landfills. The detector is equipped with sound and light alarms and remote transmission functions to ensure environmental safety assessments before operators enter and eliminate "invisible killers".

‌3. Mining and Metallurgical Industry ‌
H₂S and dust are mixed in mines and metal smelting workshops, threatening the health of workers. The equipment has an IP65 protection level and anti-dust interference design, and it can still operate stably in harsh environments.

‌4. Food Processing and Pharmaceutical Fields ‌
H₂S may be generated in fermentation processes, cold storage and other scenarios. The detector uses a 316 stainless steel shell, which is corrosion-resistant and easy to clean

 

MIC500S  Pipe Mounted Gas Concentration Detector with Relay 0MIC500S  Pipe Mounted Gas Concentration Detector with Relay 1MIC500S  Pipe Mounted Gas Concentration Detector with Relay 2MIC500S  Pipe Mounted Gas Concentration Detector with Relay 3MIC500S  Pipe Mounted Gas Concentration Detector with Relay 4MIC500S  Pipe Mounted Gas Concentration Detector with Relay 5MIC500S  Pipe Mounted Gas Concentration Detector with Relay 6MIC500S  Pipe Mounted Gas Concentration Detector with Relay 7MIC500S  Pipe Mounted Gas Concentration Detector with Relay 8
MIC500S  Pipe Mounted Gas Concentration Detector with Relay 9

 

SPECIFICATION

 

 

Gas Toxic& Harmful Gas more than 500 types Range 0-50000PPM;
0-100%LEL ;
0-100%Vol.
other ranges can be customized
Size 210×170×85mm (L×H×W) Weight 1.8 Kg
Installation method Pipeline Type
Wall Mounting Type
Display 1.7-inch high-definition color screen
Environment Temperature: -40 ℃ ~ + 70 ℃
Humidity: ≤10 ~ 95% RH (regular)
Approvals IP65; Exd Ⅱ CT6
Accessories Manual, qualification certificate, warranty card, outer packaging box
Working Voltage 12 ~ 30VDC direct current, the standard power supply for single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A
Working Method Fixed type installation, online detection, diffusion type measurement; and it is possible to select the measurement of pipeline type, flow-through type, and pump-suction type.
Connecting Cable Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100 meters, the single wire diameter ≥1.5mm; and the shielding layer will be connected to the earth.
Optional items Alarms; Wireless Transmission; Pretreatment System; SD Card;
Temperature and Humidity Measurement;
Accessory for connection with computer for monitoring.
Installation Type Accessories
(Optional configuration)
Wall mounting bracket, mounting clips for fixation on the pipes (1/2", 3/4" pipe),
stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...),
rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m),
vacuum pump (sampling distance is 40 m),
24V switching power supply, pressure reducing valve, flow meters
 

 

APPLICATION

 