Zetron CO-D4 Carbon Monoxide Sensor Miniature Size 80 to 120 kPa

Place of Origin UK
Brand Name Alphasense
Certification CE
Model Number CO Sensor
Minimum Order Quantity 1
Payment Terms L/C, D/A, D/P, T/T

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Sensitivity 420 To 650nA/ppm At 2ppm CO Response Time T90 < 25s From Zero To 10ppm CO
Pressure Range 80 To 120 KPa Humidity Range 15 To 90 % Rh Continuous
Storage Period 6 Months @ 3 To 20°C Weight < 13 G
Temperature Range -30 To 50 ℃
Highlight

CO carbon monoxide sensor

,

Miniature carbon monoxide sensor

,

CO carbon monoxide sensor

Leave a Message
Product Description

CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.
Sensors are available in the following sizes:
A: 20mm diameter, the industry standard size for portable gas detectors
B: 32mm diameter package, the best choice for fixed site applications
C: 20mm diameter with extra height for additional filter material when measuring combustion gases
D: miniature, with proven long-term performance. Sensors for the next generation of portable gas detectors
The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology. The ‘X’ sensors have low hydrogen sensitivity, as drop-in replacements for the standard ‘F’ sensors.

 
CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode PERFORMANCE
Sensitivity nA/ppm at 2ppm CO 420 to 650
Response time t90 (s) from zero to 10ppm CO < 25
Zero current nA in zero air at 20℃ +30 to -130
Noise* ±2 standard deviations (ppb equivalent) 4
Range ppm limit of performance warranty 1000
Linearity ppb CO error at full scale, linear at zero, 500ppm CO 20 to 35
Overgas limit maximum ppm for stable response to gas pulse 2000
* Tested with Alphasense ISB low noise circuit  
     
CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode LIFETIME
Zero drift ppb equivalent change/year in lab air < ±100
Sensitivity drift % change/year in lab air, monthly test < 10
Operating life months until 50% original signal (24 month warranted) > 36
     
CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode ENVIRONMENTAL
Sensitivity @ -20℃ (% output @ -20℃/output @ 20℃) @ 5ppm CO 40 to 70
Sensitivity @ 50℃ (% output @ 50℃/output @ 20℃) @ 5ppm CO 110 to 125
Zero @ -20℃ nA -30 to +30
Zero @ 50℃ nA -50 to -200
     
CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode CROSS SENSITIVITY
Filter capacity ppm·hrs H2S 250,000
H2S sensitivity % measured gas @ 5ppm H2S < 1
NO2 sensitivity % measured gas @ 5ppm NO2 < 1
Cl2 sensitivity % measured gas @ 5ppm Cl2 < 1
NO sensitivity % measured gas @ 5ppm NO < -3
SO2 sensitivity % measured gas @ 5ppm SO2 < 0.1
H2 sensitivity % measured gas @ 100ppm H2 at 20 ℃ < 10
C2H4 sensitivity % measured gas @ 100ppm C2H4 < 1
NH3 sensitivity % measured gas @ 20ppm NH3 < 0.1
     
CO-B4 Carbon Monoxide Sensor (CO Sensor) 4-Electrode KEY SPECIFICATIONS
Temperature range °C -30 to 50
Pressure range kPa 80 to 120
Humidity range % rh continuous 15 to 90
Storage period months @ 3 to 20°C (stored in sealed pot) 6
Load resistor Ω (ISB circuit is recommended) 33 to 100
Weight g < 13


Matched Transmitter board for CO-B4 CO Sensor
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors

The Individual Sensor Board (ISB) is designed for use with the Alphasense B4 family of four-electrode gas sensors. This potentiostat provides a dual channel voltage output.
A low noise bandgap provides the bias voltage for NO sensors and the ISB can measure both oxidising (CO, H2S, SO2 and NO) and reducing (O3 and NO2) gases.
The ISB is configured for specific sensors: NO, NO2, O3 and CO / H2S / SO2 .
Designed for low power applications, the ISB requires 3.5 to 6.4 stable DC supply at only 1mA.